Amp fuse keeps blowing, 00 Si EM1
#1
Honda-Tech Member
Thread Starter
Join Date: Sep 2003
Posts: 295
Likes: 0
Received 0 Likes
on
0 Posts
Alternator fuse keeps blowing, 00 Si EM1
Alternator fuse, not amp fuse.
For some reason my under dash #15 fuse, rated 7.5 amps, keeps blowing. I have replaced the ELD(electrical load detector) in the under hood fuse box, I have replaced the alternator. It will blow not 5 seconds after you strat driving down the road. Everytime......
Any ideas?
For some reason my under dash #15 fuse, rated 7.5 amps, keeps blowing. I have replaced the ELD(electrical load detector) in the under hood fuse box, I have replaced the alternator. It will blow not 5 seconds after you strat driving down the road. Everytime......
Any ideas?
#5
Honda-Tech Member
Join Date: Dec 2005
Location: Portland, OR, United States
Posts: 639
Likes: 0
Received 0 Likes
on
0 Posts
Re: Alternator fuse keeps blowing, 00 Si EM1 (hondab1015)
I had something like this but it was the wires from my si spoiler they were exposed so the neg. touched the pos. and blew a fuse which controled my horn, and brake lights. Make sure there is no bare wire.
#6
Honda-Tech Member
Join Date: Oct 2004
Location: All over ATL
Posts: 2,088
Likes: 0
Received 0 Likes
on
0 Posts
Re: Alternator fuse keeps blowing, 00 Si EM1 (hondab1015)
#15 is the Alternator fuse. The ELD unit, Gauge Assembly and PGM-FI are in this line. It looks like too that the Integrated Control Unit is connectred to it as well. These sensors in then connected to fuse 15 as well:
Secondary O2
EVAP bypass solenoid valve
EVAP Canister vent shut valve
EVAP Purge control solenoid valve
VSS
Primary O2
Alternator
These are the things to check. Hope you have a Helms.
Secondary O2
EVAP bypass solenoid valve
EVAP Canister vent shut valve
EVAP Purge control solenoid valve
VSS
Primary O2
Alternator
These are the things to check. Hope you have a Helms.
#7
Junior Member
Join Date: Sep 2005
Location: sirt texas
Posts: 493
Likes: 0
Received 0 Likes
on
0 Posts
Re: Alternator fuse keeps blowing, 00 Si EM1 (blaze the chemi)
also check your wiring harness from the alternator if there is no bare wires and sometimes wires get cut underneath the intake manifold. just an idea
Trending Topics
#8
Honda-Tech Member
Thread Starter
Join Date: Sep 2003
Posts: 295
Likes: 0
Received 0 Likes
on
0 Posts
Re: Alternator fuse keeps blowing, 00 Si EM1 (blaze the chemi)
Thanks for the help, I guess let the hunt begin. I do have a helms, and I guess since it happend when I start to move Ill start with the VSS.
#9
Honda-Tech Member
Join Date: Sep 2008
Location: hemet, ca, riverside
Posts: 69
Likes: 0
Received 0 Likes
on
0 Posts
Re: Alternator fuse keeps blowing, 00 Si EM1 (blaze the chemi)
let me know its my DD car too.