Default AC doesnt blow hard enough

I have a 94 civic dx. The a/c works and blows cold but it doesnt blow that hard. What do think is the problem? Is it the blower motor or do need to evacuate the system and recharge with new oil and freon? Whats ur thoughts It's too damn hot in Tampa
Old 06-04-2010, 04:58 PM
  #2  
Honda-Tech Member
 
shawn_crx's Avatar
 
Join Date: Sep 2003
Location: TX
Posts: 1,305
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

it's has to do with your switch or fan system, and nothing to do with freon.
Old 06-04-2010, 05:41 PM
  #3  
Technical Hero
 
HondaPartsHero's Avatar
 
Join Date: May 2002
Location: Charlotte, NC, 28227
Posts: 9,876
Likes: 0
Received 28 Likes on 20 Posts
Default Re: AC doesnt blow hard enough

does it change when you turn it from inside recirculate to outside vent?
Old 06-04-2010, 05:42 PM
  #4  
Honda-Tech Member
 
Speed_1's Avatar
 
Join Date: Jun 2006
Location: Central, Cali, US
Posts: 260
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

How about the evaporator under the dash? most of the time those get plugged up with leaves and junk making it harder for the air to flow through it.
Old 06-04-2010, 05:44 PM
  #5  
Honda-Tech Member
 
Linked's Avatar
 
Join Date: Mar 2009
Location: Chicago SPLURGE, Il
Posts: 1,561
Likes: 0
Received 1 Like on 1 Post
Default Re: AC doesnt blow hard enough

does a/c air go thru the cabin filter?

people never notice that those need to be changed occasionally as well
Old 06-04-2010, 06:51 PM
  #6  
Honda-Tech Member
 
87 SiviK Si's Avatar
 
Join Date: Sep 2003
Location: Bakersfield, CA
Posts: 234
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

92-95 civics didn't have cabin filters.
Old 06-04-2010, 07:23 PM
  #7  
Honda-Tech Member
 
burnykawizzle's Avatar
 
Join Date: Mar 2010
Location: gulf of mexico
Posts: 444
Likes: 0
Received 1 Like on 1 Post
Default Re: AC doesnt blow hard enough

sounds like the a/c blower... its behind the glove box and its a plastic big box sometimes it gets clogged up or it slowly stops to work...
Old 06-05-2010, 05:30 AM
  #8  
Honda-Tech Member
 
Matt93eg's Avatar
 
Join Date: Apr 2009
Location: Concord, NC
Posts: 1,427
Likes: 0
Received 1 Like on 1 Post
Default Re: AC doesnt blow hard enough

Originally Posted by HondaPartsHero
does it change when you turn it from inside recirculate to outside vent?
X2, OP I would check that out, sometimes the motor that moves the flap will go bad. If you have the fan on and its on Re-Fresh, when you click the Re-Circulate button the fan should start blowing more air at you. You can also drop your glove box down and see the door flap to see if its moving when you click the buttons.

Originally Posted by Linked
does a/c air go thru the cabin filter?

people never notice that those need to be changed occasionally as well
No need to notice that on a 5th gen, they don't have cabin filters like the other guy said.
Old 06-05-2010, 09:42 AM
  #9  
Honda-Tech Member
 
fungus mungus's Avatar
 
Join Date: Mar 2009
Location: The Golden State
Posts: 1,707
Received 8 Likes on 7 Posts
Default Re: AC doesnt blow hard enough

Did you check the lever on the vent on the top of your dash? If it's set towards the windshield, you won't get much coming out of the front vents as it's being directed to the defrost vents. If you pull that lever towards you, it will direct the air out the front vents.

fm
Old 09-01-2012, 12:51 AM
  #10  
Honda-Tech Member
 
Bri7man's Avatar
 
Join Date: May 2012
Posts: 4
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

Just because the cabin doesn't have a filter doesn't mean it shouldn't be cleaned. Nor that it can't become clogged. Right?
Old 09-01-2012, 12:54 AM
  #11  
Honda-Tech Member
 
Ryan Lwin's Avatar
 
Join Date: Aug 2012
Posts: 408
Likes: 0
Received 3 Likes on 2 Posts
Default Re: AC doesnt blow hard enough

Originally Posted by Bri7man
Just because the cabin doesn't have a filter doesn't mean it shouldn't be cleaned. Nor that it can't become clogged. Right?
If you try to clean that thing, it'll rip and fall apart because it's old and no one touched it. But you get fresh air. I've done it before. Just very delicate.

OP. Turn off the air vent.
Old 09-01-2012, 01:40 AM
  #12  
Honda-Tech Member
 
Bri7man's Avatar
 
Join Date: May 2012
Posts: 4
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

Originally Posted by Ryan Lwin
If you try to clean that thing, it'll rip and fall apart because it's old and no one touched it. But you get fresh air. I've done it before. Just very delicate.

OP. Turn off the air vent.
Yeah I second that.. I just got in from trying and the clips that are in the back... yeah, not worth it. -_-
Old 09-01-2012, 01:55 AM
  #13  
Honda-Tech Member
 
akelly17's Avatar
 
Join Date: Jun 2011
Posts: 256
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

buy it dinner and take it to a play, or some type of musical, that **** always gets things blowing hard.
Old 09-01-2012, 02:06 AM
  #14  
Honda-Tech Member
 
Ryan Lwin's Avatar
 
Join Date: Aug 2012
Posts: 408
Likes: 0
Received 3 Likes on 2 Posts
Default Re: AC doesnt blow hard enough

Originally Posted by akelly17
buy it dinner and take it to a play, or some type of musical, that **** always gets things blowing hard.
South Park....
Old 09-01-2012, 02:25 AM
  #15  
Honda-Tech Member
 
mxracer04's Avatar
 
Join Date: Oct 2011
Posts: 8
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

Check the blower resisitor because that controls your low, med and high on the motor. Sometimes they go bad and it will only blow on a certain speed.
Old 09-01-2012, 05:58 AM
  #16  
Honda-Tech Member
 
delsolintegra's Avatar
 
Join Date: Jul 2009
Posts: 649
Likes: 0
Received 2 Likes on 2 Posts
Default Re: AC doesnt blow hard enough

This was an old thread but if it helps anybody on my 93 del sol I had a similar problem and I dropped my fan blower motor and found a lot of old oak leaves built up in the impeller. My car hasn't been parked near an oak tree for at least 4 years that I know of Ha. So I cleaned out all the junk and I also noticed that the factory wire connector to the blower motor had a lot of corrosion/green and broken wires. This connector draws a lot of current and you get a lot of heat. I cleaned that up and it made a big difference. I also eventually changed the blower resistor and blower relay because there was a lot of current running thru the bad connection and may have effected the relay.
Old 09-01-2012, 08:08 AM
  #17  
Honda-Tech Member
 
fragmare's Avatar
 
Join Date: Jun 2012
Location: NW Indiana
Posts: 599
Likes: 0
Received 1 Like on 1 Post
Default Re: AC doesnt blow hard enough

just remove the blower fan from under glove box and clean it out. It's likely clogged up with debris and leaves and whatnot. I did the same to mine and it wasn't even all that clogged but it made a world of difference.
Old 09-03-2012, 01:39 PM
  #18  
Honda-Tech Member
 
Bri7man's Avatar
 
Join Date: May 2012
Posts: 4
Likes: 0
Received 0 Likes on 0 Posts
Default Re: AC doesnt blow hard enough

Originally Posted by fragmare
just remove the blower fan from under glove box and clean it out. It's likely clogged up with debris and leaves and whatnot. I did the same to mine and it wasn't even all that clogged but it made a world of difference.
Yeah this seems much more practical
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
theheilious
Honda Accord (1990 - 2002)
16
04-13-2018 02:23 PM
kaylawoolley
Honda CRX / EF Civic (1988 - 1991)
3
10-11-2017 03:28 AM
94 IntegraLS
Honda Civic / Del Sol (1992 - 2000)
3
10-16-2010 07:19 PM
kc_boss_816
Honda Civic / Del Sol (1992 - 2000)
11
07-10-2009 02:39 PM
digital sol
Honda Civic / Del Sol (1992 - 2000)
4
08-06-2007 04:34 PM



Quick Reply: AC doesnt blow hard enough



All times are GMT -8. The time now is 02:56 PM.