Notices

What size tungstens are you guys using?

Thread Tools
 
Search this Thread
 
Old 01-22-2008, 11:03 AM
  #1  
Honda-Tech Member
Thread Starter
 
Tony the Tiger's Avatar
 
Join Date: Mar 2000
Location: Toronto, ON, Canada
Posts: 2,859
Likes: 0
Received 0 Likes on 0 Posts
Default What size tungstens are you guys using?

I find a habit of just using a thick tungsten, but I also purchased a series of other tungsten when I first purchased my welder.

I use the 1/8" or 3/32" most of the time for almost everything.. I just sharpen them to a sharp point and have no problems doing thinner stuff.

Do any of you here ever use the thinner tungstens, like 1/25" or 1/16" for thinner gauge materials? What is the point for the thinner tungstens? When I tried using them, they just sucked... or maybe I am using them wrong or something...
Old 01-22-2008, 11:15 AM
  #2  
Honda-Tech Member
 
dave@passenger's Avatar
 
Join Date: Jun 2006
Location: Abbotsford, BC
Posts: 978
Likes: 0
Received 0 Likes on 0 Posts
Default Re: What size tungstens are you guys using? (Tony the Tiger)

For 7-55 amps I use .040", for 50-90amps I use 1/16", for 90-145 I use 3/32, and for 150-250 I use 1/8".

65% of the time I use a 1/16.
Old 01-22-2008, 11:34 AM
  #3  
Honda-Tech Member
 
legendboy's Avatar
 
Join Date: Mar 2002
Location: Calgary, AB, Canada
Posts: 2,302
Likes: 0
Received 1 Like on 1 Post
Default Re: What size tungstens are you guys using? (Tony the Tiger)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by Tony the Tiger &raquo;</TD></TR><TR><TD CLASS="quote">I find a habit of just using a thick tungsten, but I also purchased a series of other tungsten when I first purchased my welder.

I use the 1/8" or 3/32" most of the time for almost everything.. I just sharpen them to a sharp point and have no problems doing thinner stuff.

Do any of you here ever use the thinner tungstens, like 1/25" or 1/16" for thinner gauge materials? What is the point for the thinner tungstens? When I tried using them, they just sucked... or maybe I am using them wrong or something...</TD></TR></TABLE>

i use 3/32 for everything
Old 01-22-2008, 12:23 PM
  #4  
OG Fabricator
 
weiRtech's Avatar
 
Join Date: Feb 2005
Location: Burlington, Ont., Canada
Posts: 1,864
Likes: 0
Received 1 Like on 1 Post
Default

i ran out of 3/32" a while ago and started using my 1/16" because i had lots of them... they are handy for getting into tight spots on collectors and stuff, but most of the time i just use 3/32" i find with a gas lense you can even pull the 1/16" out further from the cup as well to get at tight spots.

side note: if you are ever in need of flanges let me know. i understand how nice it is to have suppliers for materials that are local.

aaron
905-802-4703
Old 01-22-2008, 12:26 PM
  #5  
Honda-Tech Member
 
k24em2's Avatar
 
Join Date: Apr 2005
Location: Lincoln, Ne, USA
Posts: 1,895
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (weiRtech)

3/32 for everything
Old 01-22-2008, 12:39 PM
  #6  
Honda-Tech Member
 
Bailhatch's Avatar
 
Join Date: Sep 2002
Location: ME
Posts: 5,517
Likes: 0
Received 1 Like on 1 Post
Default Re: (k24em2)

.040", 3/32" and 1/8". I use 3/32 at least 90% of the time.
Old 01-22-2008, 02:24 PM
  #7  
Honda-Tech Member
 
Desir Performance's Avatar
 
Join Date: Aug 2006
Location: NYC
Posts: 520
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (k24em2)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by k24em2 &raquo;</TD></TR><TR><TD CLASS="quote">3/32 for everything</TD></TR></TABLE>

Yup same here. You can use a smaller tungsten for lower amp but why not just use a size that you can go down to 30 amp and still able to go over 100 with out changing it. for tight places i just use a gas lense with a smaller cup.
Old 01-22-2008, 02:38 PM
  #8  
Honda-Tech Member
 
dave@passenger's Avatar
 
Join Date: Jun 2006
Location: Abbotsford, BC
Posts: 978
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (Desir Performance)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by Desir Performance &raquo;</TD></TR><TR><TD CLASS="quote">

but why not just use a size that you can go down to 30 amp and still able to go over 100 with out changing it</TD></TR></TABLE>

Answer: Better arc control.

Don't get me wrong a lot of times we just use whatever is in the torch given we aren't exceeding its heat limit because the tungsten will split and spit. But when you are doing a bunch of a certain wall thickness a properly sized tungsten helps give you that edge on quality.
Old 01-22-2008, 03:46 PM
  #9  
Honda-Tech Member
 
CarTunr22's Avatar
 
Join Date: Mar 2005
Location: Indianapolis, In, U.S.A.
Posts: 148
Likes: 0
Received 0 Likes on 0 Posts
Default

I use 1/16 as often as possible. Like Dave said there is better control with the thiner stuff. Its like going from a blunt end to a sharpened end.
Old 01-22-2008, 03:52 PM
  #10  
Honda-Tech Member
 
AspectIndustries's Avatar
 
Join Date: Sep 2003
Location: Boost is good
Posts: 3,166
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (CarTunr22)

Red 3/32 for Everything
Old 01-22-2008, 07:56 PM
  #11  
Honda-Tech Member
 
bigTom's Avatar
 
Join Date: Oct 2000
Location: Zoo York
Posts: 4,534
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (AspectIndustries)

I use 1/16 about 70% of the time. Almost all my DC welding is with 1/16th. Aluminum i use 3/32 and 1/8th for the thick stuff (&gt;.125)
Old 01-23-2008, 11:10 PM
  #12  
Honda-Tech Member
Thread Starter
 
Tony the Tiger's Avatar
 
Join Date: Mar 2000
Location: Toronto, ON, Canada
Posts: 2,859
Likes: 0
Received 0 Likes on 0 Posts
Default Re: What size tungstens are you guys using? (Tony the Tiger)

Great to know.. Thanks for the feedback everyone

I weld a lot of thin and thick materials together (flanges to tubing, fittings to sheet metal, etc...), and seems like the best tungsten to use is a thick 3/32" and 1/8"... I still never have an opporunity to use anything smaller than a 3/32"
Old 01-23-2008, 11:59 PM
  #13  
Honda-Tech Member
 
.RTErnie's Avatar
 
Join Date: May 2002
Location: BeLlInGhAm, Wa
Posts: 3,599
Likes: 0
Received 0 Likes on 0 Posts
Default Re: What size tungstens are you guys using? (Tony the Tiger)

For 0-50 amps I use .040", for 50-135amps I use 1/16", for 135-200 I use 3/32
^ Im pretty close to dave@passenger with this one...

It also varies with your welding technique. I've noticed when using an undersized tungsten it discolors my weld bead. I just figured this out tonight. 190 amps doing a manual pulse with 1/16" Ceriated(has a higher capacity for heat)

For aluminum...I've taken to using gigantuan sizes. 3/32 for the most thin gauge... sharpened and truncated. and 1/8" for .250"

(I used to melt down torch assemblies back in the day...i wore the big mig gloves and walked the torch around my fingers because it would burn them if I held it in one spot! lol) btw..this was in 2002. I've come a long way since then
Old 01-24-2008, 07:47 AM
  #14  
Honda-Tech Member
 
DESTROYER's Avatar
 
Join Date: Apr 2006
Location: MESA, AZ, USA
Posts: 622
Likes: 0
Received 0 Likes on 0 Posts
Default

I have found that using 1/16" on anything thicker than 16ga nets me a crappy weld.

I use 3/32" on stuff from roll cages to thick walled turbo manifolds. 1/16" for anything thinner.
Old 01-24-2008, 09:48 AM
  #15  
Honda-Tech Member
 
.RTErnie's Avatar
 
Join Date: May 2002
Location: BeLlInGhAm, Wa
Posts: 3,599
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (DESTROYER)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by DESTROYER &raquo;</TD></TR><TR><TD CLASS="quote">I have found that using 1/16" on anything thicker than 16ga nets me a crappy weld. </TD></TR></TABLE>

do you know why this is? only thing I could think was it was depositing tungsten into the weld....
Old 01-24-2008, 09:53 AM
  #16  
Honda-Tech Member
 
S2KP's Avatar
 
Join Date: Feb 2003
Location: Denver, CO
Posts: 992
Likes: 0
Received 1 Like on 1 Post
Default

3/32 for most.
Old 01-24-2008, 11:12 AM
  #17  
Honda-Tech Member
 
DESTROYER's Avatar
 
Join Date: Apr 2006
Location: MESA, AZ, USA
Posts: 622
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (.RTErnie)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by .RTErnie &raquo;</TD></TR><TR><TD CLASS="quote">

do you know why this is? only thing I could think was it was depositing tungsten into the weld....</TD></TR></TABLE>
I assume as much is happening, besides that running too much amperage through anything that isn't big enough to conduct will yield less net amperage coming out of the end of the torch. But I will assume that the thoriated particles are blowing out of the tip due to the massive amperage flow.

This is all in skepticism however
Old 01-24-2008, 02:50 PM
  #18  
Honda-Tech Member
 
.RTErnie's Avatar
 
Join Date: May 2002
Location: BeLlInGhAm, Wa
Posts: 3,599
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (DESTROYER)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by DESTROYER &raquo;</TD></TR><TR><TD CLASS="quote">
I assume as much is happening, besides that running too much amperage through anything that isn't big enough to conduct will yield less net amperage coming out of the end of the torch. But I will assume that the thoriated particles are blowing out of the tip due to the massive amperage flow.

This is all in skepticism however </TD></TR></TABLE>

i use ceriated :-P you have a point tho. I'm going to do a manifold with 3/32 and see if I can tell a difference
Old 01-24-2008, 03:37 PM
  #19  
Member
 
david@didrace.com's Avatar
 
Join Date: Nov 2003
Location: Lemont, IL, USA
Posts: 1,247
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (dave@passenger)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by dave@passenger &raquo;</TD></TR><TR><TD CLASS="quote">

Answer: Better arc control.

Don't get me wrong a lot of times we just use whatever is in the torch given we aren't exceeding its heat limit because the tungsten will split and spit. But when you are doing a bunch of a certain wall thickness a properly sized tungsten helps give you that edge on quality.</TD></TR></TABLE>

Yup. I was taught to use the thinnest tungsten possible. It's pretty easy to figure out at what amperage each diameter tungsten is going to melt on your machine.

It's kind of like asking 'What amperage should I use to weld this .125" steel plate?'. It depends.
Old 01-24-2008, 03:58 PM
  #20  
Junior Member
 
ROTARY's Avatar
 
Join Date: Nov 2006
Posts: 588
Likes: 0
Received 0 Likes on 0 Posts
Default

i use 3/32 1.5% lanthanated for everything... machine - dynasty 200dx.
Old 01-24-2008, 04:27 PM
  #21  
Honda-Tech Member
 
Syner-G-Racing LLC's Avatar
 
Join Date: Feb 2004
Location: IN STORES NOW
Posts: 933
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (david@didrace.com)

I use the smallest size capable of runing the amps I need...ends up being 1/16 or 3/32 most of the time. I switched from thoriated awhile back to ceriated and lanthanated...Its just as good as thoriated minus the hazmat issues.
Old 01-24-2008, 05:38 PM
  #22  
Honda-Tech Member
iTrader: (3)
 
IN VTEC's Avatar
 
Join Date: Jan 2000
Location: Bloomington, IN, USA
Posts: 10,180
Likes: 0
Received 3 Likes on 3 Posts
Default Re: (Syner-G-Racing LLC)

Isn't a fair rule of thumb to use a diameter of tungsten no smaller than the width of the gap you're trying to weld?

For example, if you've got a notched tube that wasn't notched perfectly to fit over a tube of a larger diameter, and the gap was 1/8" wide at the largest point...you would use nothing smaller than 1/8".
Old 01-24-2008, 06:35 PM
  #23  
Honda-Tech Member
 
dave@passenger's Avatar
 
Join Date: Jun 2006
Location: Abbotsford, BC
Posts: 978
Likes: 0
Received 0 Likes on 0 Posts
Default Re: (IN VTEC)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by IN VTEC &raquo;</TD></TR><TR><TD CLASS="quote">Isn't a fair rule of thumb to use a diameter of tungsten no smaller than the width of the gap you're trying to weld?

For example, if you've got a notched tube that wasn't notched perfectly to fit over a tube of a larger diameter, and the gap was 1/8" wide at the largest point...you would use nothing smaller than 1/8".</TD></TR></TABLE>

No, not at all. AS mentioned above tungsten size is based on amperage/heat going through the tungsten.

A thing I thought I would mention to all the guys who only run one size of tungsten, the smaller tungstens will give you better arc "cone" shape, sure you can just run a finer point on your 3/32 tungsten when doing thin stuff but the actual shape of the cone/arc is much different than if you were running a fine point on a .040" tungsten. Try it out and look for the differences, it can make a good difference.
Old 01-25-2008, 09:00 AM
  #24  
Honda-Tech Member
 
GTibunny16v's Avatar
 
Join Date: Feb 2003
Location: Somewhere in, CT
Posts: 459
Likes: 0
Received 0 Likes on 0 Posts
Default Re: What size tungstens are you guys using? (dave@passenger)

<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by dave@passenger &raquo;</TD></TR><TR><TD CLASS="quote">For 7-55 amps I use .040", for 50-90amps I use 1/16", for 90-145 I use 3/32, and for 150-250 I use 1/8".

65% of the time I use a 1/16.</TD></TR></TABLE>


Old 01-25-2008, 04:21 PM
  #25  
Honda-Tech Member
 
CoreyR's Avatar
 
Join Date: Aug 2004
Posts: 1,864
Likes: 0
Received 1 Like on 1 Post
Default Re: What size tungstens are you guys using? (GTibunny16v)

i usually use 3/32 on everything but i think im gonna try 1/16 on the next manifold i build to see how it works out.


Quick Reply: What size tungstens are you guys using?



All times are GMT -8. The time now is 04:37 AM.