Torque specs, and valve clearance on a B18C type R (jdm)
#1
Thread Starter
Join Date: Mar 2005
Location: Glendale, AZ, USA
Posts: 4
Likes: 0
Received 0 Likes
on
0 Posts
Torque specs, and valve clearance on a B18C type R (jdm)
I'm rebuilding my motor, does anyone know the specs for the torque settings and the valve clearance or where it can be found? For a 97' B18C Type R motor.
Thank you in advance!
Thank you in advance!
#2
Honda-Tech Member
Join Date: Oct 2003
Location: Armed and Ready
Posts: 14,394
Likes: 0
Received 0 Likes
on
0 Posts
Re: Torque specs, and valve clearance on a B18C type R (dtmpower)
#3
Honda-Tech Member
Join Date: Nov 2004
Location: socal, CA
Posts: 268
Likes: 0
Received 0 Likes
on
0 Posts
Re: Torque specs, and valve clearance on a B18C type R (dtmpower)
i'm not sure about jdm motors but usdm c5's are .006 - .007" intake and .007 - .008" exhaust *cold. i don't think there is any difference between jdm and usdm heads so i'd say it'd be safe to go with usdm valve lash specs.
#4
Honda-Tech Member
Join Date: Sep 2004
Location: florida
Posts: 2,878
Likes: 0
Received 0 Likes
on
0 Posts
Re: Torque specs, and valve clearance on a B18C type R (hypeR speed)
<TABLE WIDTH="90%" CELLSPACING=0 CELLPADDING=0 ALIGN=CENTER><TR><TD>Quote, originally posted by hypeR speed »</TD></TR><TR><TD CLASS="quote">i'm not sure about jdm motors but usdm c5's are .006 - .007" intake and .007 - .008" exhaust *cold. i don't think there is any difference between jdm and usdm heads so i'd say it'd be safe to go with usdm valve lash specs.</TD></TR></TABLE>
when you say .006-.007int and .007-.008 ex
does that mean you can run .006in & .007ex or .007in & .008ex
what about .006in & .008ex or .007in & .007ex?
If i can not hear the valves ticking that mean they are still in specs and i do not in an adjustment?
when you say .006-.007int and .007-.008 ex
does that mean you can run .006in & .007ex or .007in & .008ex
what about .006in & .008ex or .007in & .007ex?
If i can not hear the valves ticking that mean they are still in specs and i do not in an adjustment?
#5
Honda-Tech Member
Join Date: Nov 2004
Location: socal, CA
Posts: 268
Likes: 0
Received 0 Likes
on
0 Posts
Re: Torque specs, and valve clearance on a B18C type R (realis9)
anything between those values would be in spec, so .006 would be slightly loose and .007 would be a little tighter. if you havent checked it in a while it wouldnt hurt to check
Trending Topics
Thread
Thread Starter
Forum
Replies
Last Post
tigasTT
All Motor / Naturally Aspirated
1
12-15-2015 02:46 PM
pacifico
Honda Civic / Del Sol (1992 - 2000)
7
02-11-2004 10:52 AM